Logo GapZero

THE IMPLANT FREE OF BACTERIAL MICROLEAKAGE *

The result of a unique quality control

A
11-degree conical connection for a load distribution respectful with the bone and perfect seal.
B
Manufacturing tolerances up to 7 microns for a perfect adjustment.
C
Verification of 100% of the production to guarantee the highest implant and abutment quality standards.

* Only with Ticare abutments.

Perfect fit at 20 and 30 N

(*) BACTERIAL MICROLEAKAGE AT THE ABUTMENT-IMPLANT INTERFACE, IN VITRO STUDY

Larrucea C, Aparicio C, Olivares D, Padilla C, Barrera A, Lobos O
Clinical Implant Dentistry and Related Research 2018;1-8

THE RESULT

The RESULT: the implant free of bacterial microleakage* that reduces the risk of periimplantitis and maintains the marginal bone level.

GAP 0

The paper published in 2018 on ticare inhex® implants shows that there is no bacterial microleakage at 20 and 30 N torque.

MAINTENANCE OF THE MARGINAL BONE LEVEL

Ticare inhex® studies show and excellent maintenance of bone level, with only 0.2 mm bone loss at 1- and 3-year follow up

Five articles confirm the existence of gap 0 at the connection

The last scientific study carried out compares the implant/abutment connection of 7 brands. Ticare proves to be the only implant free of bacterial microleakage in all the samples tested.

Download the study

Five articles confirm the existence of gap 0 at the connection:

COMPARATIVE STUDY OF BACTERIAL MICROFILTRATION IN THE IMPLANT-ABUTMENT INTERFACE, WITH STRAIGHT AND CONICAL INTERNAL CONNECTIONS, IN VITRO
Larrucea V. Carlos, Navarro C. Carlos, Larrucea SM. Karina, Boda K. Sunil, Padilla E. Carlos, Lobos G. Olga
Clinical and Experimental Dental Research 2021 April, 1-11    Abstract 

EFFECTS OF TIGHTENING TORQUE ON SCREW STRESS AND FORMATION OF IMPLANT ABUTMENT MICROGAPS: A FINITE ELEMENT ANALYSIS
Honorio Tonin BS, He Y, Ye N, Chew HP, Fok A
The Journal of Prosthetic Dentistry 2021 Jan. 17:s0022-3913(20)30749-6    Abstract

CONTACT ANALYSIS OF GAP FORMATION AT DENTAL IMPLANT-ABUTMENT INTERFACE UNDER OBLIQUE LOADING: A NUMERICAL-EXPERIMENTAL STUDY
He Y, Fok A, Aparicio C, Teng W.
Clinical Implant Dentistry and Related Research 2019 Aug; 21(4):741-752     Abstract

BACTERIAL MICROLEAKAGE AT THE ABUTMENT-IMPLANT INTERFACE, IN VITRO STUDY
Carlos Larrucea, Aparicio Conrado, Denise Olivares, Carlos Padilla, Andrea Barrera, Olga Lobos
Clinical Implant Dentistry and Related Research 2018 January; 1-8     Abstract

MICROLEAKAGE OF THE PROSTHETIC ABUTMENT/IMPLANT INTERFACE WITH INTERNAL AND EXTERNAL CONNECTION: IN VITRO STUDY
Carlos Larrucea Verdugo, Guido Jaramillo Núnez, Ariel Acevedo Avila, Carlos Larrucea San Martín
Clinical Oral Implants Research 2013 May, 1-6       Abstract

The expert opinion

1/5

Ticare in SEPA Málaga 2022

Dr Hom-Lay Wang talk about Ticare Perio Hybrid and how useful it is in Sepa Málaga

Prof Mariano Sanz present Ticare-gapZero's clinical and scientific evidence

What are the experts's opinions about the benefits of gap "0"?

What implant/abutment connection system ensures success in oral rehabilitation? Dr Carlos Larrucea

    More information

    Contact us to know more about gapZero

    *I've read the Privacy policy
    1

    BASIC INFORMATION ON DATA PROTECTION

    Responsible for the treatment: MOZO GRAU S.A.

    To authorize the following data treatment, please click the corresponding box for each case:

    Sending information by different means, including electronic ones, related to the activity of Mozo Grau/Ticare. YesNo

    You can consult additional information on Data Protection and security measures in our Privacy Policy

    References

    1.

    Larrucea Verdugo, C. y cols. Bacterial microleakage at the abutment-implant interface, in vitro study. Clinical Implant Dentistry and Related Research. Accepted: 2018.

    2.

    Larrucea Verdugo, C. y cols. Microleakage of the prosthetic abutment/implant interface with internal and external connection: In vitro study. Clinical Oral Implants Research. Accepted: 2013

    3.

    Marco Esposito, Alberto González, Miguel Peñarrocha, Raúl Fernández, Anna Trullenque, Erta Xhanari, David Peñarrocha. Natural or palatal positioning of immediate post-extractive implants in the aesthetic zone?. 1-year results of a multicentre randomised controlled trial. Eur J Oral Implantol 2018;11(2):189:200.

    4.

    David Peñarrocha-Oltra, Miguel Peñarrocha Diago, Raúl Fernández Encinas, Daniela Rita Ippolito, Erta Xhanari, Marco Esposito. Natural or palatal positioning of immediate post-extractive implants in the aesthetic zone?. 3-year results of a multicentre randomised controlled trial. The International Journal of Oral&Maxillofacial Implant 2019; 12(2):181-194

    Follow us

    ¡Suscríbete para estar al día de todas las novedades!

    * indicates required