Logo GapZero

THE IMPLANT FREE OF BACTERIAL MICROLEAKAGE *

The result of a unique quality control

A
11-degree conical connection for a load distribution respectful with the bone and perfect seal.
B
Manufacturing tolerances up to 7 microns for a perfect adjustment.
C
Verification of 100% of the production to guarantee the highest implant and abutment quality standards.

* Only with Ticare abutments.

Perfect fit at 20 and 30 N
https://www.ticareimplants.com/wp/wp-content/uploads/2022/03/gapzero-monochrome.jpg

(*) BACTERIAL MICROLEAKAGE AT THE ABUTMENT-IMPLANT INTERFACE, IN VITRO STUDY

Larrucea C, Aparicio C, Olivares D, Padilla C, Barrera A, Lobos O
Clinical Implant Dentistry and Related Research 2018;1-8

THE RESULT

The RESULT: the implant free of bacterial microleakage* that reduces the risk of periimplantitis and maintains the marginal bone level.

GAP 0

The paper published in 2018 on ticare inhex® implants shows that there is no bacterial microleakage at 20 and 30 N torque.

MAINTENANCE OF THE MARGINAL BONE LEVEL

Ticare inhex® studies show and excellent maintenance of bone level, with only 0.2 mm bone loss at 1- and 3-year follow up

Five articles confirm the existence of gap 0 at the connection

The last scientific study carried out compares the implant/abutment connection of 7 brands. Ticare proves to be the only implant free of bacterial microleakage in all the samples tested.

Download the study

The expert opinion

1/5

Ticare in SEPA Málaga 2022

Dr Hom-Lay Wang talk about Ticare Perio Hybrid and how useful it is in Sepa Málaga

Prof Mariano Sanz present Ticare-gapZero's clinical and scientific evidence

What are the experts's opinions about the benefits of gap "0"?

What implant/abutment connection system ensures success in oral rehabilitation? Dr Carlos Larrucea

    More information

    Contact us to know more about gapZero

    *I've read the Privacy policy
    1

    BASIC INFORMATION ON DATA PROTECTION

    Responsible for the treatment: MOZO GRAU S.A.

    To authorize the following data treatment, please click the corresponding box for each case:

    Sending information by different means, including electronic ones, related to the activity of Mozo Grau/Ticare. YesNo

    You can consult additional information on Data Protection and security measures in our Privacy Policy

    References

    1.

    Larrucea Verdugo, C. y cols. Bacterial microleakage at the abutment-implant interface, in vitro study. Clinical Implant Dentistry and Related Research. Accepted: 2018.

    2.

    Larrucea Verdugo, C. y cols. Microleakage of the prosthetic abutment/implant interface with internal and external connection: In vitro study. Clinical Oral Implants Research. Accepted: 2013

    3.

    Marco Esposito, Alberto González, Miguel Peñarrocha, Raúl Fernández, Anna Trullenque, Erta Xhanari, David Peñarrocha. Natural or palatal positioning of immediate post-extractive implants in the aesthetic zone?. 1-year results of a multicentre randomised controlled trial. Eur J Oral Implantol 2018;11(2):189:200.

    4.

    David Peñarrocha-Oltra, Miguel Peñarrocha Diago, Raúl Fernández Encinas, Daniela Rita Ippolito, Erta Xhanari, Marco Esposito. Natural or palatal positioning of immediate post-extractive implants in the aesthetic zone?. 3-year results of a multicentre randomised controlled trial. The International Journal of Oral&Maxillofacial Implant 2019; 12(2):181-194

    Síguenos en nuestras redes sociales

    ¡Suscríbete para estar al día de todas las novedades!

    * indicates required