{"id":4476,"date":"2021-07-01T11:36:45","date_gmt":"2021-07-01T09:36:45","guid":{"rendered":"https:\/\/www.ticareimplants.com\/?post_type=estudios-medicos&#038;p=4476"},"modified":"2021-07-01T11:36:45","modified_gmt":"2021-07-01T09:36:45","slug":"effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time","status":"publish","type":"estudios-medicos","link":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/","title":{"rendered":"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time"},"content":{"rendered":"<p><strong>OBJECTIVE<\/strong><\/p>\n<p>The purpose of our study was to determine the effect of two UV-C light sources with a wavelength of 254 nm and an energy of 1400 W\/cm3 to obtain a hydrophilic surface, comparing two UV-C sources with different powers (6 and 85 W) and a control group.<\/p>\n<p><strong>MATERIAL AND METHODS<\/strong><\/p>\n<p>Ten titanium discs were randomly divided into three groups: a control group, a 6 W group, and an 85 W group. A drop of double-distilled, deionized, and sterile 10 \u00b5L water was applied to each of the discs. Each disc was immediately photographed in a standardized and perpendicular manner. Measurements were taken based on the irradiation time (15, 30, 60, and 120 min).<\/p>\n<p><strong>RESULTS<\/strong><\/p>\n<p>UVC irradiation improved the control values in both groups. There was no difference in its effect between the 6W group and the other groups during the first 30 min. However, after 60 min and up to 120 min, 85 W had a significantly stronger effect. The contact angles with the 85Wultraviolet light source at 60 and 120 min were 19.43 and 31.41, respectively, whereas the contact angles for the 6 W UVC source were 73.8 and 61.45.<\/p>\n<p><strong>CONCLUSION<\/strong><\/p>\n<p>Power, rather than time, was shown to be the most important and significant factor for obtaining hydrophilic surfaces. Within the limitations of this study, we concluded that the ideal power to improve the wettability of titanium with an RBM-TC surface is 85 watts applied for 60 min at a wavelength of 254 nm. We consider that these findings can improve the biological process of osseointegration in implant therapy and offer us clues to the use of UVC in dental offices.<\/p>\n","protected":false},"parent":0,"template":"","medio-publicacion":[],"tematica-publicacion":[],"class_list":["post-4476","estudios-medicos","type-estudios-medicos","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time\" \/>\n<meta property=\"og:description\" content=\"OBJECTIVE The purpose of our study was to determine the effect of two UV-C light sources with a wavelength of 254 nm and an energy of 1400 W\/cm3 to obtain a hydrophilic surface, comparing two UV-C sources with different powers (6 and 85 W) and a control group. MATERIAL AND METHODS Ten titanium discs were randomly divided into three groups: a control group, a 6 W group, and an 85 W group. A drop of double-distilled, deionized, and sterile 10 \u00b5L water was applied to each of the discs. Each disc was immediately photographed in a standardized and perpendicular manner. Measurements were taken based on the irradiation time (15, 30, 60, and 120 min). RESULTS UVC irradiation improved the control values in both groups. There was no difference in its effect between the 6W group and the other groups during the first 30 min. Read the whole content\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/\" \/>\n<meta property=\"og:site_name\" content=\"Ticare\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ticareimplants\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ticareimplants\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/\",\"url\":\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/\",\"name\":\"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time\",\"isPartOf\":{\"@id\":\"https:\/\/www.ticareimplants.com\/#website\"},\"datePublished\":\"2021-07-01T09:36:45+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ticareimplants.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Estudios m\u00e9dicos\",\"item\":\"https:\/\/www.ticareimplants.com\/estudios-medicos\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ticareimplants.com\/#website\",\"url\":\"https:\/\/www.ticareimplants.com\/\",\"name\":\"Ticare\",\"description\":\"Tissue Care Philosophy\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ticareimplants.com\/search\/{search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/","og_locale":"en_US","og_type":"article","og_title":"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time","og_description":"OBJECTIVE The purpose of our study was to determine the effect of two UV-C light sources with a wavelength of 254 nm and an energy of 1400 W\/cm3 to obtain a hydrophilic surface, comparing two UV-C sources with different powers (6 and 85 W) and a control group. MATERIAL AND METHODS Ten titanium discs were randomly divided into three groups: a control group, a 6 W group, and an 85 W group. A drop of double-distilled, deionized, and sterile 10 \u00b5L water was applied to each of the discs. Each disc was immediately photographed in a standardized and perpendicular manner. Measurements were taken based on the irradiation time (15, 30, 60, and 120 min). RESULTS UVC irradiation improved the control values in both groups. There was no difference in its effect between the 6W group and the other groups during the first 30 min. Read the whole content","og_url":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/","og_site_name":"Ticare","article_publisher":"https:\/\/www.facebook.com\/ticareimplants\/","twitter_card":"summary_large_image","twitter_site":"@ticareimplants","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/","url":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/","name":"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time","isPartOf":{"@id":"https:\/\/www.ticareimplants.com\/#website"},"datePublished":"2021-07-01T09:36:45+00:00","breadcrumb":{"@id":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-of-photofunctionalization-with-6-w-or-85-w-uv-c-on-the-degree-of-wettability-of-rbm-titanium-in-relation-to-the-irradiation-time\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ticareimplants.com\/en\/"},{"@type":"ListItem","position":2,"name":"Estudios m\u00e9dicos","item":"https:\/\/www.ticareimplants.com\/estudios-medicos\/"},{"@type":"ListItem","position":3,"name":"Effect of photofunctionalization with 6 w or 85 w uv-c on the degree of wettability of rbm titanium in relation to the irradiation time"}]},{"@type":"WebSite","@id":"https:\/\/www.ticareimplants.com\/#website","url":"https:\/\/www.ticareimplants.com\/","name":"Ticare","description":"Tissue Care Philosophy","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ticareimplants.com\/search\/{search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/estudios-medicos\/4476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/estudios-medicos"}],"about":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/types\/estudios-medicos"}],"wp:attachment":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/media?parent=4476"}],"wp:term":[{"taxonomy":"medio-publicacion","embeddable":true,"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/medio-publicacion?post=4476"},{"taxonomy":"tematica-publicacion","embeddable":true,"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/tematica-publicacion?post=4476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}