{"id":4443,"date":"2021-06-28T17:23:58","date_gmt":"2021-06-28T15:23:58","guid":{"rendered":"https:\/\/www.ticareimplants.com\/?post_type=estudios-medicos&#038;p=4443"},"modified":"2021-06-28T17:23:58","modified_gmt":"2021-06-28T15:23:58","slug":"effect-on-osseointegration-of-two-implant-macro-designs-a-histomorphometric-analysis-of-bicortically-installed-implants-in-different-topographic-sites-of-rabbits-tibiae","status":"publish","type":"estudios-medicos","link":"https:\/\/www.ticareimplants.com\/en\/medical-publications\/effect-on-osseointegration-of-two-implant-macro-designs-a-histomorphometric-analysis-of-bicortically-installed-implants-in-different-topographic-sites-of-rabbits-tibiae\/","title":{"rendered":"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae"},"content":{"rendered":"<p><strong>OBJECTIVE<\/strong><\/p>\n<p>To evaluate the effect of two different implant macro-designs on the sequential osseointegration at bicortically installed implants in the rabbit tibia. A further aim is to compare the osseointegration at different topographic zones.<\/p>\n<p><strong>MATERIAL AND METHODS<\/strong><\/p>\n<p>27 New Zealand rabbits were implemented. Two implants, one for each macro-design (Ticare Inhex\u00ae or Ticare Quattro\u00ae, Mozo-Grau, Valladolid, Spain), were randomly implanted in the diaphysis or metaphysis of each tibia. The flaps were sutured to allow a submerged healing. The animals were sacrificed after 2, 4 or 8 weeks. Ground sections were prepared and analyzed.<\/p>\n<p><strong>RESULTS<\/strong><\/p>\n<p>No statistically significant differences were found between the two groups for newly formed bone in contact with the implant surface, being about 16%, 19% and 33% in both groups, after 2, 4, and 8 weeks of healing. Bone apposition was slightly higher in the diaphysis, reaching values of 36.4% in the diaphysis, and 29.3% in the metaphysis at 8 weeks of healing. It was observed that the implant position showed a statistical significance regarding BIC values at 4 and 8 weeks (p&lt;0.05). Multivariate analysis fails to detect statistical significant differences for the interaction between implant designs and topographic site. Ticare Quattro\u00ae design had a slight better BIC values at diaphysis sites across healing stages, but without reaching a statistical significance.<\/p>\n<p><strong>CONCLUSION<\/strong><\/p>\n<p>The both implant macro-designs provided similar degrees of osseointegration. Bone morphometry and density may affect bone apposition onto the implant surface. The apposition rates were slightly better in diaphysis compared to metaphysis.<\/p>\n","protected":false},"parent":0,"template":"","medio-publicacion":[],"tematica-publicacion":[],"class_list":["post-4443","estudios-medicos","type-estudios-medicos","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae\" \/>\n<meta property=\"og:description\" content=\"OBJECTIVE To evaluate the effect of two different implant macro-designs on the sequential osseointegration at bicortically installed implants in the rabbit tibia. A further aim is to compare the osseointegration at different topographic zones. MATERIAL AND METHODS 27 New Zealand rabbits were implemented. Two implants, one for each macro-design (Ticare Inhex\u00ae or Ticare Quattro\u00ae, Mozo-Grau, Valladolid, Spain), were randomly implanted in the diaphysis or metaphysis of each tibia. The flaps were sutured to allow a submerged healing. The animals were sacrificed after 2, 4 or 8 weeks. Ground sections were prepared and analyzed. RESULTS No statistically significant differences were found between the two groups for newly formed bone in contact with the implant surface, being about 16%, 19% and 33% in both groups, after 2, 4, and 8 weeks of healing. Bone apposition was slightly higher in the diaphysis, Read the whole content\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/\" \/>\n<meta property=\"og:site_name\" content=\"Ticare\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ticareimplants\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ticareimplants\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/\",\"url\":\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/\",\"name\":\"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae\",\"isPartOf\":{\"@id\":\"https:\/\/www.ticareimplants.com\/#website\"},\"datePublished\":\"2021-06-28T15:23:58+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ticareimplants.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Estudios m\u00e9dicos\",\"item\":\"https:\/\/www.ticareimplants.com\/estudios-medicos\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ticareimplants.com\/#website\",\"url\":\"https:\/\/www.ticareimplants.com\/\",\"name\":\"Ticare\",\"description\":\"Tissue Care Philosophy\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ticareimplants.com\/search\/{search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/","og_locale":"en_US","og_type":"article","og_title":"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae","og_description":"OBJECTIVE To evaluate the effect of two different implant macro-designs on the sequential osseointegration at bicortically installed implants in the rabbit tibia. A further aim is to compare the osseointegration at different topographic zones. MATERIAL AND METHODS 27 New Zealand rabbits were implemented. Two implants, one for each macro-design (Ticare Inhex\u00ae or Ticare Quattro\u00ae, Mozo-Grau, Valladolid, Spain), were randomly implanted in the diaphysis or metaphysis of each tibia. The flaps were sutured to allow a submerged healing. The animals were sacrificed after 2, 4 or 8 weeks. Ground sections were prepared and analyzed. RESULTS No statistically significant differences were found between the two groups for newly formed bone in contact with the implant surface, being about 16%, 19% and 33% in both groups, after 2, 4, and 8 weeks of healing. Bone apposition was slightly higher in the diaphysis, Read the whole content","og_url":"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/","og_site_name":"Ticare","article_publisher":"https:\/\/www.facebook.com\/ticareimplants\/","twitter_card":"summary_large_image","twitter_site":"@ticareimplants","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/","url":"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/","name":"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae","isPartOf":{"@id":"https:\/\/www.ticareimplants.com\/#website"},"datePublished":"2021-06-28T15:23:58+00:00","breadcrumb":{"@id":"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ticareimplants.com\/medical-publications\/efecto-sobre-la-osteointegracion-de-dos-macrodisenos-de-implantes-un-analisis-histomorfometrico-de-implantes-colocados-bicorticalmente-en-diferentes-sitios-topograficos-de-tibias-de-conejo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ticareimplants.com\/en\/"},{"@type":"ListItem","position":2,"name":"Estudios m\u00e9dicos","item":"https:\/\/www.ticareimplants.com\/estudios-medicos\/"},{"@type":"ListItem","position":3,"name":"Effect on osseointegration of two implant macro-designs: a histomorphometric analysis of bicortically installed implants in different topographic sites of rabbit\u2019s tibiae"}]},{"@type":"WebSite","@id":"https:\/\/www.ticareimplants.com\/#website","url":"https:\/\/www.ticareimplants.com\/","name":"Ticare","description":"Tissue Care Philosophy","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ticareimplants.com\/search\/{search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/estudios-medicos\/4443","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/estudios-medicos"}],"about":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/types\/estudios-medicos"}],"wp:attachment":[{"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/media?parent=4443"}],"wp:term":[{"taxonomy":"medio-publicacion","embeddable":true,"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/medio-publicacion?post=4443"},{"taxonomy":"tematica-publicacion","embeddable":true,"href":"https:\/\/www.ticareimplants.com\/en\/wp-json\/wp\/v2\/tematica-publicacion?post=4443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}